Technocover Total Services Logo

Technocover Duty of Care

The combination of meeting the criteria for “Duty of Care” and achieving an accurate “Risk Assessment Security Level” is truly a genuine investment. The process can be quite challenging, however, especially as an obligation now exists to assess the risk of potential injury to those entering the site without authority. The cost of selection of the correct access solution will be repaid many times over in both increased efficiency and the reassurance that operations personnel are protected from injury during unsociable hours and in all weather conditions.

ESTABLISHING YOUR SECURITY/DUTY OF CARE REQUIREMENTS

1. The Designer shall ensure that due consideration is given to the Specifiers responsibility to Duty of Care “Product Responsibility” – Minimum Features for Safe Operation and Protection of Operatives. These requirements should be checked against each specific application. In addition, Duty of Care “Site Responsibility” – Potential Injury to Vandals and Minors and Environmental Impact must be taken into account.

Every effort must be made to:

  • Guard against potential injury to persons not in the employ of the site owner.

  • Secure the site against acts of vandalism or extortion which might impact upon the environment.

2. The Designer shall ensure that adequate consideration is given to site specific variable risks such as site location and history of previous incidents.

3. Protective physical security levels shall be measurable against a recognised security standard.

GUIDE TO APPROPRIATE LEVELS OF SECURITY

All our products have been given a ‘level of security‘ rating using the guide below.

Technocover Risk Assessment Level 2 Logo - Yellow RISK ASSESSMENT LEVEL 2 SECURITY
LOW RISK
 – 
Yellow Level 2
Typical rural locations with minor risk of vandalism. Not for areas of a high security nature. Products approved by LPCB to LPS 1175 Security Rating 2 are indicated by the LPCB approval mark.
Technocover Risk Assessment Level 3 Logo - Blue

RISK ASSESSMNT LEVEL 3
MEDIUM RISK – Blue Level 3
Typical rural locations with major risk of vandalism or urban situation with minor risk of vandalism. Increased level of security to deter vandals. Products approved by LPCB to LPS 1175 Security Rating 3 are indicated by the LPCB approval mark. 

Technocover Risk Assessment Level 4 Logo - Green RISK ASSESSMENT LEVEL 4 SECURITY
HIGH RISK
 – 
Green Level 4
Typical urban sites and locations with a history of serious vandalism. High level of security. Products approved by LPCB to LPS 1175 Security Rating 4 are indicated by the LPCB approval mark.
Technocover Risk Assessment Level 5 Logo - Red

RISK ASSESSMENT LEVEL 5 SECURITY
EXTREME RISK
 – 
Red Level 5
Products for use on specifically selected locations, designed to maximise the protection of sensitive sites. Products approved for terrorist/extortionist sites i.e. V.P. (Vulnerable Points) sites.

 



Our highly experienced consultancy team is available to make recommendations on choosing the correct, “fit for purpose,” access products by quantifying actual operational health and safety benefits and then applying the appropriate risk assessment security level. Email our Technical Consultants here – techadvice@technocover.co.uk.

We also recognise the need for improvement, not just with regard to security and duty of care issues, and actively take steps toward achieving best practice solutions to the various problems encountered on site.

TECHNOCOVER RISK ASSESSMENT GUIDE*

This has been created using our own Risk Assessment Level coding system which is also shown on the applicable PDF for every product shown on this website. Definitions for our Level 2, 3 , 4 and 5 risk assessment can be found above.

Definition of site  Risk Assessment Level Requirement for Sites
Technocover Risk Assessment Level 2 Logo - Yellow Technocover Risk Assessment Level 3 Logo - Blue Technocover Risk Assessment Level 4 Logo - Green Technocover Risk Assessment Level 5 Logo - Red
RURAL Locations
Secure perimiter – No history of vandalism    
Open Access – No history of vandalism    
Secure perimiter – Minor history of vandalism    
Open Access – Minor history of vandalism    
Secure perimiter – Major history of vandalism    
Open Access – Major history of vandalism    
URBAN Locations
Secure perimiter – No history of vandalism    
Open Access – No history of vandalism    
Secure perimiter – Minor history of vandalism    
Open Access – Minor history of vandalism    
Secure perimiter – Major history of vandalism    
Open Access – Major history of vandalism    
DESIGNATED VULNERABLE POINTS (typical examples)
Government Locations    
Ministry of Defence Establishments    
Hospitals    
Power Stations    
Gas Pumping Stations    
Fuel Refineries    
Airports    
Ferry Terminals    
Environmentally Sensitive Areas    

*This table is a GUIDE ONLY. Information herein is not to be taken in preference where existing Government/Infrastructure sector guidelines or specifications are in place. Technocover are continually developing security products acting as key facilitators in providing clients with security solutions to overcome vulnerability issues to meet the latest asset security standards.  

 

DUTY OF CARE POTENTIAL INJURY TO VANDALS & MINORS - SITE SECURITY

DUTY OF CARE - VARIABLE RISK

The designer shall, as far as is reasonably practicable, ensure that every effort is made, during product design, to guard against potential injury to persons not in the employment of the site owner.

 

DUTY OF CARE ENVIRONMENTAL IMPACT - SITE SECURITY

DUTY OF CARE - VARIABLE RISK

The designer shall assess the potential environmental impact as a result of acts of vandalism and/or extortion.

Technocover Site Service Vehicles

Please REGISTER if you require technical datasheets on any of our products.

For technical assistance on any of our products please use the HELP button.

For details of access cover fall protection options click here.